Magna-Power Electronics XR Series II DC Power Supplies


Magna-Power Electronics XR Series II DC Power Supplies

 

 

  • 2 kW to 8 kW in a 2U package
  • Models from 0-5 VDC to 0-1000 VDC
  • Optically isolated user I/O circuitry standard
  • High efficiency operation: Up to 88% efficiency on select models
  • RS-232 interface standard with SCPI Commands
  • Optional GPIB, USB, Ethernet (LXI-C), RS-485 interfaces
  • Over Voltage and Over Current shutdown standard
  • Certified LabWindows/CVI, LabView, and IVI Drivers
  • Programmable Output Modulation: Emulates user-defined power profiles
  • Automatic Voltage/Current Crossover
  • Front Panel Calibration
  • Made in USA
  • ONE Year Warranty

Additional Product Information

 

Innovative and Scalable

Magna-Power Electronics XR Series combines the best of DC power processing with microprocessor embedded control. A combination of high and medium frequency power processing technologies improves response, shrinks package size, and reduces cost. XR Series power supplies are current fed and are more tolerant to abusive loads than conventional switching power supplies. This technology allows the power supply to operate under short-circuit conditions, open-circuit conditions, and everything in between. XR Series power supplies offer both master/slave parallel and series operation. This enables two or more power supplies to be placed in parallel for increased output current or in series for increased output voltage. With master/slave operation, power supplies operate at near equal voltage and current. XR Series power supplies can operate as a voltage source or current source depending on the control settings and load conditions. If the power supply is operating as a voltage source and the load increases to a point beyond the current command setting, the power supply automatically crosses over to current mode control and operates as a current source at that setting.

Fully Configurable
XR Series power supplies can be configured through the front panel for different applications. The power supply can be programmed to have its control functions accessible from the front panel, rear connector, RS-232, optional GPIB, optional USB, or optional LXI-certified Ethernet communications. Sensing can be established at the output terminal of the power supply or through a rear terminal block for sensing at the load. An external interlock can be set to enable operation only when an external connection is made. Even calibration has been simplified with front panel access to calibration digital potentiometers.

Isolated External I/O for Automation
Using the rear 37-pin I/O connector, the XR Series power supplies can be completely controlled and monitored using external signals. The voltage, current, over voltage trip, and over current trip set points are set by applying a 0-10 Vdc signal. Each diagnostic condition is given a designated pin, which reads 10 Vdc when high. Also, the power supply features an external interlock, which when enabled, allows the power supply to be tied in with other emergency stop equipment. All these pins are isolated to earth-ground as standard - no additional isolation equipment necessary!

Designed for Safety
XR Series power supplies have extensive diagnostic functions - all of which, when activated, take command to shut down the system. Diagnostic functions include phase loss, excessive thermal conditions, over voltage trip, over current trip, fuse clearing, and program line. Program line monitors externally applied analog set point signals to insure they are within the specified range. Upon a diagnostic fault condition, main power is disconnected and the diagnostic condition is latched into memory. Pressing the clear key clears the memory. All diagnostic functions can be monitored through a rear connector. Furthermore, control functions can also be set through the rear connector to allow simultaneous control of one or more XR Series units. XR Series supplies have three levels of over voltage/current protection: shutdown of controlling insulated gate bipolar transistors (IGBT's), disconnect of main power, and input fuses. After an over voltage/current trip condition, the supply must be reset.

XR Version Front Panel
XR models provide stepless analog control from front panel potentiometers. With a simple configuration change, the power supply can be programmed from the rear I/O connector or through software on one of the communications bus. The XR Series has 100 memory states available to program voltage, current, over voltage trip, over current trip, and time period in software.
More Info >>

XRC Version Front Panel
XRC models only allow control from the rear connector or by RS-232/GPIB/Ethernet communications. These models are intended for process control applications where front panel controls and displays are not required or desired.
More Info >>

 

Magna-Power SoftwareRemote Interface Software
The Remote Interface Software is shipped with all XR Series power supplies. The software provides the user with a quick method to operate a Magna-Power Electronics' power supply under computer control. The Remote Interface Software has six windows: the Virtual Control Panel, Command Panel, Register Panel, Calibration Panel, Firmware Panel, and Modulation Panel. The Virtual Control Panel emulates the front panel of the XR Series power supply, the Command panel programs and reads SCPI commands with user friendly buttons, the Register Panel programs and reads registers, the Calibration Panel enables calibration of the digital potentiometers, the Firmware Panel enables the program stored internal to the power supply to be upgraded, and the Modulation Panel eases programming of modulation parameters.

 

2 kW Models

Model

Voltage (V)

Current (A)

XR5-375

0-5

0-375

XR10-200

0-10

0-200

XR16-125

0-16

0-125

XR20-100

0-20

0-100

XR32-62

0-32

0-62

XR40-50

0-40

0-50

XR50-40

0-50

0-40

XR80-25

0-80

0-25

XR100-20

0-100

0-20

XR125-16

0-125

0-16

XR160-12

0-160

0-12

XR200-10

0-200

0-10

XR250-8

0-250

0-8

XR375-5.3

0-375

0-5.3

XR400-5.0

0-400

0-5.0

XR500-4.0

0-500

0-4.0

XR600-3.3

0-600

0-3.3

XR800-2.5

0-800

0-2.5

XR1000-2.0

0-1000

0-2.0

4 kW Models

Model

Voltage (V)

Current (A)

XR10-375

0-10

0-375

XR16-250

0-16

0-250

XR20-200

0-20

0-200

XR32-124

0-32

0-124

XR40-100

0-40

0-100

XR50-80

0-50

0-80

XR80-50

0-80

0-50

XR100-40

0-100

0-40

XR125-32

0-125

0-32

XR160-24

0-160

0-24

XR200-20

0-200

0-20

XR250-16

0-250

0-16

XR375-10.6

0-375

0-10.6

XR400-10.0

0-400

0-10.0

XR500-8.0

0-500

0-8.0

XR600-6.6

0-600

0-6.6

XR800-5.0

0-800

0-5.0

XR1000-4.0

0-1000

0-4.0

6 kW Models

Model

Voltage (V)

Current (A)

XR16-375

0-16

0-375

XR20-300

0-20

0-300

XR32-186

0-32

0-186

XR40-150

0-40

0-150

XR50-120

0-50

0-120

XR80-75

0-80

0-75

XR100-60

0-100

0-60

XR125-48

0-125

0-48

XR160-36

0-160

0-36

XR200-30

0-200

0-30

XR250-24

0-250

0-24

XR375-15.9

0-375

0-15.9

XR400-15.0

0-400

0-15.0

XR500-12.0

0-500

0-12

XR600-9.9

0-600

0-9.9

XR800-7.5

0-800

0-7.5

XR1000-6.0

0-1000

0-6.0

 

8 kW Models

Model

Voltage (V)

Current (A)

XR20-375

0-20

0-375

XR32-250

0-32

0-250

XR40-200

0-40

0-200

XR50-160

0-50

0-160

XR80-100

0-80

0-100

XR100-80

0-100

0-80

XR125-64

0-125

0-64

XR160-50

0-160

0-50

XR200-40

0-200

0-40

XR250-32

0-250

0-32

XR375-21.3

0-375

0-21.3

XR400-20.0

0-400

0-20

XR500-16.0

0-500

0-16

XR600-13.3

0-600

0-13.3

XR800-10.0

0-800

0-10

XR1000-8.0

0-1000

0-8

 

 

Input Voltage (Must be specified at time of order)

1 phase, 2 wire + ground (for 2 kW models only)
208 VAC, 1φ (operating range 187 - 229 VAC) add $100
240 VAC, 1φ (operating range 216 - 264 VAC) add $100

3 phase, 3 wire + ground (all models)
208 VAC, 3φ (operating range 187 - 229 VAC)
240 VAC, 3φ (operating range 216 - 264 VAC)
380 VAC, 3φ (operating range 342 - 418 VAC)
415 VAC, 3φ (operating range 373 - 456 VAC)
440 VAC, 3φ (operating range 396 - 484 VAC)
480 VAC, 3φ (operating range 432 - 528 VAC)

 

Model Ordering System

Series

Front Panel

Voltage (Vdc)

-

Current (Adc)

/

Input Voltage

-

Interface Option

XR

Blank: Standard Panel
C: Computer (Blank) Panel

See Tables

-

See Tables

/

208SP
240SP
208
240
380
415
440
480

-

USB
GPIB
Ethernet

Example: XR600-10/208-GPIB

NOTE:

·         GPIB and Ethernet are optional and must be specified at time of order.

·         Power cords are not included.

·         For other models please contact dynams@airtelmail.in

 

 

Southern Dynamics (P) Ltd, 110 Nelson Manickam Road, Chennai 600 029. India
Tel: 91-44-2374 1203 Fax: 91-44-2827 4702 Email: dynams@airtelmail.in  www.southerndynamics.com

Updated Sept 2011 ©2011  Southern Dynamics (P) Ltd Webmaster