|
Magna-Power Electronics XR Series II DC Power Supplies
|

|
-
2 kW to 8 kW in a 2U package
-
Models from 0-5 VDC to 0-1000 VDC
-
Optically isolated user I/O circuitry standard
-
High efficiency operation: Up to 88% efficiency on select
models
-
RS-232 interface standard with SCPI Commands
-
Optional GPIB, USB, Ethernet (LXI-C), RS-485 interfaces
-
Over Voltage and Over Current shutdown standard
-
Certified LabWindows/CVI, LabView, and IVI Drivers
-
Programmable Output Modulation: Emulates user-defined
power profiles
-
Automatic Voltage/Current Crossover
-
Front Panel Calibration
-
Made in USA
-
ONE Year Warranty
|
Additional Product Information
Innovative
and Scalable
Magna-Power Electronics XR
Series combines the best of DC power processing with
microprocessor embedded control. A combination of high and
medium frequency power processing technologies improves
response, shrinks package size, and reduces cost. XR Series
power supplies are current fed and are more tolerant to abusive
loads than conventional switching power supplies. This
technology allows the power supply to operate under
short-circuit conditions, open-circuit conditions, and
everything in between. XR Series power supplies offer both
master/slave parallel and series operation. This enables two or
more power supplies to be placed in parallel for increased
output current or in series for increased output voltage. With
master/slave operation, power supplies operate at near equal
voltage and current. XR Series power supplies can operate as a
voltage source or current source depending on the control
settings and load conditions. If the power supply is operating
as a voltage source and the load increases to a point beyond the
current command setting, the power supply automatically crosses
over to current mode control and operates as a current source at
that setting.
Fully
Configurable
XR
Series power supplies can be configured through the front panel
for different applications. The power supply can be programmed
to have its control functions accessible from the front panel,
rear connector, RS-232, optional GPIB, optional USB, or optional
LXI-certified Ethernet communications. Sensing can be
established at the output terminal of the power supply or
through a rear terminal block for sensing at the load. An
external interlock can be set to enable operation only when an
external connection is made. Even calibration has been
simplified with front panel access to calibration digital
potentiometers.
Isolated
External I/O for Automation
Using the rear 37-pin I/O connector, the XR Series power
supplies can be completely controlled and monitored using
external signals. The voltage, current, over voltage trip, and
over current trip set points are set by applying a 0-10 Vdc
signal. Each diagnostic condition is given a designated pin,
which reads 10 Vdc when high. Also, the power supply features an
external interlock, which when enabled, allows the power supply
to be tied in with other emergency stop equipment. All these
pins are isolated to earth-ground as standard - no additional
isolation equipment necessary!
Designed
for Safety
XR
Series power supplies have extensive diagnostic functions - all
of which, when activated, take command to shut down the system.
Diagnostic functions include phase loss, excessive thermal
conditions, over voltage trip, over current trip, fuse clearing,
and program line. Program line monitors externally applied
analog set point signals to insure they are within the specified
range. Upon a diagnostic fault condition, main power is
disconnected and the diagnostic condition is latched into
memory. Pressing the clear key clears the memory. All diagnostic
functions can be monitored through a rear connector.
Furthermore, control functions can also be set through the rear
connector to allow simultaneous control of one or more XR Series
units. XR Series supplies have three levels of over
voltage/current protection: shutdown of controlling insulated
gate bipolar transistors (IGBT's), disconnect of main power, and
input fuses. After an over voltage/current trip condition, the
supply must be reset.
XR Version
Front Panel
XR models provide stepless analog control from front panel
potentiometers. With a simple configuration change, the power
supply can be programmed from the rear I/O connector or through
software on one of the communications bus. The XR Series has 100
memory states available to program voltage, current, over
voltage trip, over current trip, and time period in software.
More Info
>>
XRC Version
Front Panel
XRC models only allow control from the rear connector or by
RS-232/GPIB/Ethernet communications. These models are intended
for process control applications where front panel controls and
displays are not required or desired.
More Info
>>
|
Remote
Interface Software
The Remote Interface Software is shipped with all XR Series
power supplies. The software provides the user with a quick
method to operate a Magna-Power Electronics' power supply
under computer control. The Remote Interface Software has
six windows: the Virtual Control Panel, Command Panel,
Register Panel, Calibration Panel, Firmware Panel, and
Modulation Panel. The Virtual Control Panel emulates the
front panel of the XR Series power supply, the Command panel
programs and reads SCPI commands with user friendly buttons,
the Register Panel programs and reads registers, the
Calibration Panel enables calibration of the digital
potentiometers, the Firmware Panel enables the program
stored internal to the power supply to be upgraded, and the
Modulation Panel eases programming of modulation parameters.
|
|
2
kW Models |
|
Model |
Voltage (V) |
Current (A) |
|
XR5-375 |
0-5 |
0-375 |
|
XR10-200 |
0-10 |
0-200 |
|
XR16-125 |
0-16 |
0-125 |
|
XR20-100 |
0-20 |
0-100 |
|
XR32-62 |
0-32 |
0-62 |
|
XR40-50 |
0-40 |
0-50 |
|
XR50-40 |
0-50 |
0-40 |
|
XR80-25 |
0-80 |
0-25 |
|
XR100-20 |
0-100 |
0-20 |
|
XR125-16 |
0-125 |
0-16 |
|
XR160-12 |
0-160 |
0-12 |
|
XR200-10 |
0-200 |
0-10 |
|
XR250-8 |
0-250 |
0-8 |
|
XR375-5.3 |
0-375 |
0-5.3 |
|
XR400-5.0 |
0-400 |
0-5.0 |
|
XR500-4.0 |
0-500 |
0-4.0 |
|
XR600-3.3 |
0-600 |
0-3.3 |
|
XR800-2.5 |
0-800 |
0-2.5 |
|
XR1000-2.0 |
0-1000 |
0-2.0 |
|
|
4
kW Models |
|
Model |
Voltage (V) |
Current (A) |
|
XR10-375 |
0-10 |
0-375 |
|
XR16-250 |
0-16 |
0-250 |
|
XR20-200 |
0-20 |
0-200 |
|
XR32-124 |
0-32 |
0-124 |
|
XR40-100 |
0-40 |
0-100 |
|
XR50-80 |
0-50 |
0-80 |
|
XR80-50 |
0-80 |
0-50 |
|
XR100-40 |
0-100 |
0-40 |
|
XR125-32 |
0-125 |
0-32 |
|
XR160-24 |
0-160 |
0-24 |
|
XR200-20 |
0-200 |
0-20 |
|
XR250-16 |
0-250 |
0-16 |
|
XR375-10.6 |
0-375 |
0-10.6 |
|
XR400-10.0 |
0-400 |
0-10.0 |
|
XR500-8.0 |
0-500 |
0-8.0 |
|
XR600-6.6 |
0-600 |
0-6.6 |
|
XR800-5.0 |
0-800 |
0-5.0 |
|
XR1000-4.0 |
0-1000 |
0-4.0 |
|
|
6
kW Models |
|
Model |
Voltage (V) |
Current (A) |
|
XR16-375 |
0-16 |
0-375 |
|
XR20-300 |
0-20 |
0-300 |
|
XR32-186 |
0-32 |
0-186 |
|
XR40-150 |
0-40 |
0-150 |
|
XR50-120 |
0-50 |
0-120 |
|
XR80-75 |
0-80 |
0-75 |
|
XR100-60 |
0-100 |
0-60 |
|
XR125-48 |
0-125 |
0-48 |
|
XR160-36 |
0-160 |
0-36 |
|
XR200-30 |
0-200 |
0-30 |
|
XR250-24 |
0-250 |
0-24 |
|
XR375-15.9 |
0-375 |
0-15.9 |
|
XR400-15.0 |
0-400 |
0-15.0 |
|
XR500-12.0 |
0-500 |
0-12 |
|
XR600-9.9 |
0-600 |
0-9.9 |
|
XR800-7.5 |
0-800 |
0-7.5 |
|
XR1000-6.0 |
0-1000 |
0-6.0 |
|
|
|
8
kW Models |
|
Model |
Voltage (V) |
Current (A) |
|
XR20-375 |
0-20 |
0-375 |
|
XR32-250 |
0-32 |
0-250 |
|
XR40-200 |
0-40 |
0-200 |
|
XR50-160 |
0-50 |
0-160 |
|
XR80-100 |
0-80 |
0-100 |
|
XR100-80 |
0-100 |
0-80 |
|
XR125-64 |
0-125 |
0-64 |
|
XR160-50 |
0-160 |
0-50 |
|
XR200-40 |
0-200 |
0-40 |
|
XR250-32 |
0-250 |
0-32 |
|
XR375-21.3 |
0-375 |
0-21.3 |
|
XR400-20.0 |
0-400 |
0-20 |
|
XR500-16.0 |
0-500 |
0-16 |
|
XR600-13.3 |
0-600 |
0-13.3 |
|
XR800-10.0 |
0-800 |
0-10 |
|
XR1000-8.0 |
0-1000 |
0-8 |
|
Input
Voltage
(Must be specified at time of order)
1 phase, 2 wire + ground (for 2 kW models only)
208 VAC, 1φ (operating range 187 - 229 VAC) add $100
240 VAC, 1φ (operating range 216 - 264 VAC) add $100
3
phase, 3 wire + ground (all models)
208 VAC,
3φ (operating range 187 - 229 VAC)
240 VAC, 3φ (operating range 216 - 264 VAC)
380 VAC, 3φ (operating range 342 - 418 VAC)
415 VAC, 3φ (operating range 373 - 456 VAC)
440 VAC, 3φ (operating range 396 - 484 VAC)
480 VAC, 3φ (operating range 432 - 528 VAC) |
|
Model Ordering
System |
|
Series |
Front Panel |
Voltage (Vdc) |
- |
Current (Adc) |
/ |
Input Voltage |
- |
Interface Option
|
|
XR |
Blank: Standard
Panel
C: Computer (Blank) Panel |
See Tables |
- |
See Tables |
/ |
208SP
240SP
208
240
380
415
440
480 |
- |
USB
GPIB
Ethernet |
|
Example:
XR600-10/208-GPIB |
NOTE:
·
GPIB and Ethernet are optional and must be specified at time of
order.
·
Power cords are not included.
·
For other models please contact
dynams@airtelmail.in
|